6
to 18 volts, reverse polarity
protected, negative or
positive ground. Not
compatible with 6 volt
electrical systems as these
may drop below 4 volts during
cranking
Coil current
limit
4.5
amps (externally limited by
ballast resistor on XR700).
Internal short circuit
protection limit set at 7
amps
RPM
range
6,000 RPM (RPM range higher
for 4 and 6 cylinder
engines)
P
rimary voltage
output
400
volts (inductive
discharge)
Primary energy
output
60
millijoules with PS20/40
coil
Peak
spark gap
current
60
milliamps with PS20/40
coil
Spark
duration
300 microseconds at 6,000
RPM
Dimensions
3-1/2"L x
3"W x 1-1/2"H, 1 lb
Product Reviews for FAST700-0231 - FAST